DocumentCode :
108769
Title :
Including Spatial Information in Nonlinear Inversion MR Elastography Using Soft Prior Regularization
Author :
McGarry, Matthew ; Johnson, Curtis L. ; Sutton, Bradley P. ; Van Houten, Elijah Ew ; Georgiadis, John G. ; Weaver, John B. ; Paulsen, Keith D.
Author_Institution :
Thayer Sch. of Eng., Dartmouth Coll., Hanover, NH, USA
Volume :
32
Issue :
10
fYear :
2013
fDate :
Oct. 2013
Firstpage :
1901
Lastpage :
1909
Abstract :
Tissue displacements required for mechanical property reconstruction in magnetic resonance elastography (MRE) are acquired in a magnetic resonance imaging (MRI) scanner, therefore, anatomical information is available from other imaging sequences. Despite its availability, few attempts to incorporate prior spatial information in the MRE reconstruction process have been reported. This paper implements and evaluates soft prior regularization (SPR), through which homogeneity in predefined spatial regions is enforced by a penalty term in a nonlinear inversion strategy. Phantom experiments and simulations show that when predefined regions are spatially accurate, recovered property values are stable for SPR weighting factors spanning several orders of magnitude, whereas inaccurate segmentation results in bias in the reconstructed properties that can be mitigated through proper choice of regularization weighting. The method was evaluated in vivo by estimating viscoelastic mechanical properties of frontal lobe gray and white matter for five repeated scans of a healthy volunteer. Segmentations of each tissue type were generated using automated software, and statistically significant differences between frontal lobe gray and white matter were found for both the storage modulus and loss modulus . Provided homogeneous property assumptions are reasonable, SPR produces accurate quantitative property estimates for tissue structures which are finer than the resolution currently achievable with fully distributed MRE.
Keywords :
biomechanics; biomedical MRI; brain; image reconstruction; image segmentation; medical image processing; phantoms; MRI scanner; SPR weighting factor; frontal lobe gray matter; frontal lobe white matter; magnetic resonance imaging; mechanical property reconstruction; nonlinear inversion MR elastography; nonlinear inversion strategy; phantom; regularization weighting; soft prior regularization; spatial information; tissue displacement; tissue type segmentation; Image reconstruction; Image segmentation; In vivo; Material properties; Mechanical factors; Minimization; Phantoms; Brain; magnetic resonance elastography (MRE); nonlinear inversion; soft prior; Brain; Elastic Modulus; Elasticity Imaging Techniques; Humans; Imaging, Three-Dimensional; Male; Nonlinear Dynamics; Phantoms, Imaging; Young Adult;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/TMI.2013.2268978
Filename :
6542013
Link To Document :
بازگشت