DocumentCode
1088077
Title
Reflections in anechoic chambers in 100-200 GHz range
Author
Lehto, A. ; Tuovinen, J. ; Raisanen, Antti
Author_Institution
Radio Lab., Helsinki Univ. of Technol., Espoo, Finland
Volume
27
Issue
19
fYear
1991
Firstpage
1708
Lastpage
1709
Abstract
Three anechoic chambers have been tested at 110 and 183 GHz. Typical sidewall reflectivity levels are about -60 dB at 110 GHz and -50 dB at 183 GHz measured with pyramidal horns which have a gain of 20 dB. Backwall reflectivity levels are about -35 dB at 110 GHz and -25 dB at 183 GHz.
Keywords
anechoic chambers; electromagnetic wave reflection; microwave measurement; 100 to 200 GHz; 110 GHz; 183 GHz; 20 dB; anechoic chambers; backwall reflectivity levels; pyramidal horns; sidewall reflectivity levels;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el:19911063
Filename
132898
Link To Document