DocumentCode :
1088233
Title :
Effect of radial rotor ventilation ducts on cage motor equivalent circuit parameters
Author :
Williamson, S. ; Flack, T.J.
Author_Institution :
Dept. of Eng., Cambridge Univ., UK
Volume :
141
Issue :
3
fYear :
1994
fDate :
5/1/1994 12:00:00 AM
Firstpage :
155
Lastpage :
162
Abstract :
A three-dimensional finite-element model is used to investigate the effect that radial ventilation ducts have on the equivalent-circuit parameters of cage motors. It is shown that ducts change rotor resistance at starting, and an approximate method is proposed to allow for this effect. Detailed flux calculations are also used to verify some of the duct factors that are used for reactance calculations
Keywords :
electric reactance; electric resistance; equivalent circuits; finite element analysis; machine theory; magnetic flux; rotors; squirrel cage motors; starting; cage motor equivalent circuit parameters; finite-element model; flux calculations; radial rotor ventilation ducts; reactance calculations; rotor resistance; starting; three-dimensional;
fLanguage :
English
Journal_Title :
Electric Power Applications, IEE Proceedings -
Publisher :
iet
ISSN :
1350-2352
Type :
jour
DOI :
10.1049/ip-epa:19941088
Filename :
285762
Link To Document :
بازگشت