Abstract
A three-dimensional finite-element model is used to investigate the effect that radial ventilation ducts have on the equivalent-circuit parameters of cage motors. It is shown that ducts change rotor resistance at starting, and an approximate method is proposed to allow for this effect. Detailed flux calculations are also used to verify some of the duct factors that are used for reactance calculations
Keywords
electric reactance; electric resistance; equivalent circuits; finite element analysis; machine theory; magnetic flux; rotors; squirrel cage motors; starting; cage motor equivalent circuit parameters; finite-element model; flux calculations; radial rotor ventilation ducts; reactance calculations; rotor resistance; starting; three-dimensional;