DocumentCode
1088661
Title
Wavenumber measurements of sub-Doppler spectral lines of Rb at 1.3 mu m and 1.5 mu m
Author
Sasada, Hiroyuki
Author_Institution
Dept. of Phys., Keio Univ., Yokohama, Japan
Volume
4
Issue
11
fYear
1992
Firstpage
1307
Lastpage
1309
Abstract
1.3- mu m and 1.5- mu m distributed-feedback semiconductor lasers have been frequency stabilized to sub-Doppler resonances of the 5P/sub 1/2/ to 6S/sub 1/2/ and the 5P/sub 3/2/ to 4D/sub 3/2,5/2/ transitions of /sup 85,87/Rb atoms, respectively. Using these stabilized lasers, the absolute wavenumbers of the transitions have been measured interferometrically with an accuracy of 2*10/sup -7/.<>
Keywords
distributed feedback lasers; frequency measurement; infrared spectra of atoms; laser frequency stability; light interferometry; measurement standards; rubidium; semiconductor lasers; /sup 85/Rb; /sup 87/Rb; 1.3 micron; 1.5 micron; Rb; accuracy; distributed-feedback semiconductor lasers; frequency references; frequency stabilisation; interferometric measurement; sub-Doppler resonances; sub-Doppler spectral lines; wavenumber measurements; Fiber lasers; Frequency; Laser feedback; Laser noise; Laser stability; Laser transitions; Laser tuning; Pump lasers; Ring lasers; Semiconductor lasers;
fLanguage
English
Journal_Title
Photonics Technology Letters, IEEE
Publisher
ieee
ISSN
1041-1135
Type
jour
DOI
10.1109/68.166978
Filename
166978
Link To Document