DocumentCode
1089851
Title
Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging
Author
Wygant, Ira O. ; Zhuang, Xuefeng ; Yeh, David T. ; Oralkan, Ömer ; Ergun, A. Sanli ; Karaman, Mustafa ; Khuri-Yakub, Butrus T.
Author_Institution
Stanford Univ., Stanford
Volume
55
Issue
2
fYear
2008
fDate
2/1/2008 12:00:00 AM
Firstpage
327
Lastpage
342
Abstract
For three-dimensional (3D) ultrasound imaging, connecting elements of a two-dimensional (2D) transducer array to the imaging system´s front-end electronics is a challenge because of the large number of array elements and the small element size. To compactly connect the transducer array with electronics, we flip-chip bond a 2D 16 times 16-element capacitive micromachined ultrasonic transducer (CMUT) array to a custom-designed integrated circuit (IC). Through-wafer interconnects are used to connect the CMUT elements on the top side of the array with flip-chip bond pads on the back side. The IC provides a 25-V pulser and a transimpedance preamplifier to each element of the array. For each of three characterized devices, the element yield is excellent (99 to 100% of the elements are functional). Center frequencies range from 2.6 MHz to 5.1 MHz. For pulse-echo operation, the average -6-dB fractional bandwidth is as high as 125%. Transmit pressures normalized to the face of the transducer are as high as 339 kPa and input-referred receiver noise is typically 1.2 to 2.1 rnPa/ radicHz. The flip-chip bonded devices were used to acquire 3D synthetic aperture images of a wire-target phantom. Combining the transducer array and IC, as shown in this paper, allows for better utilization of large arrays, improves receive sensitivity, and may lead to new imaging techniques that depend on transducer arrays that are closely coupled to IC electronics.
Keywords
biomedical electronics; biomedical equipment; biomedical ultrasonics; echo; flip-chip devices; integrated circuits; micromachining; phantoms; sensor arrays; ultrasonic transducers; IC electronics; capacitive micromachined ultrasonic transducer; flip-chip bond; frequency 2.6 MHz to 5.1 MHz; front-end electronics; input-referred receiver noise; integrated circuit; pressure 339 kPa; pulse-echo operation; pulser; receive sensitivity; synthetic aperture images; three-dimensional ultrasound imaging; transimpedance preamplifier; two-dimensional CMUT arrays; two-dimensional transducer array; voltage 25 V; volumetric ultrasound imaging; wire-target phantom; Algorithms; Electronics, Medical; Equipment Design; Equipment Failure Analysis; Image Enhancement; Image Interpretation, Computer-Assisted; Imaging, Three-Dimensional; Reproducibility of Results; Sensitivity and Specificity; Signal Processing, Computer-Assisted; Systems Integration; Transducers; Ultrasonography;
fLanguage
English
Journal_Title
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher
ieee
ISSN
0885-3010
Type
jour
DOI
10.1109/TUFFC.2008.652
Filename
4460868
Link To Document