Noninvasive Average Flow and Differential Pressure Estimation for an Implantable Rotary Blood Pump Using Dimensional Analysis
Author :
Lim, Einly ; Karantonis, Dean M. ; Reizes, John A. ; Cloherty, Shaun L. ; Mason, David G. ; Lovell, Nigel H.
Author_Institution :
Grad. Sch. of Biomed. Eng., Univ. of New South Wales, Sydney, NSW
Volume :
55
Issue :
8
fYear :
2008
Firstpage :
2094
Lastpage :
2101
Abstract :
Accurate noninvasive average flow and differential pressure estimation of implantable rotary blood pumps (IRBPs) is an important practical element for their physiological control. While most attempts at developing flow and differential pressure estimate models have involved purely empirical techniques, dimensional analysis utilizes theoretical principles of fluid mechanics that provides valuable insights into parameter relationships. Based on data obtained from a steady flow mock loop under a wide range of pump operating points and fluid viscosities, flow and differential pressure estimate models were thus obtained using dimensional analysis. The algorithm was then validated using data from two other VentrAssist IRBPs. Linear correlations between estimated and measured pump flow over a flow range of 0.5 to 8.0 L/min resulted in a slope of 0.98 (R 2 = 0.9848). The average flow error was 0.20 plusmn 0.14 L/min (mean plusmn standard deviation) and the average percentage error was 5.79%. Similarly, linear correlations between estimated and measured pump differential pressure resulted in a slope of 1.027 (R 2 = 0.997) over a pressure range of 60 to 180 mmHg. The average differential pressure error was 1.84 plusmn 1.54 mmHg and the average percentage error was 1.51%.
Keywords :
blood; blood flow measurement; blood pressure measurement; cardiovascular system; prosthetics; viscosity; VentrAssist IRBP; average flow error; differential pressure error; flow estimation; implantable rotary blood pump; pressure estimation; Australia; Biological materials; Biomedical engineering; Biomedical measurements; Blood; Fluid flow measurement; Implants; Pressure control; Pressure measurement; Pumps; Velocity measurement; Dimensional analysis; flow estimation; implantable rotary blood pump; implantable rotary blood pump (IRBP); left ventricular assist device; left ventricular assist device (LVAD); Algorithms; Blood Flow Velocity; Blood Pressure; Equipment Failure Analysis; Heart-Assist Devices; Humans;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/TBME.2008.919723
Filename :
4463646
Link To Document :
بازگشت