• DocumentCode
    1092973
  • Title

    Thyratron operation using Helium for high-power and high-repetition rate applications

  • Author

    Guha, Shekhar ; Braun, Chris ; Kunc, Joseph ; Gundersen, Martin

  • Author_Institution
    University of Southern California, Los Angeles, CA
  • Volume
    31
  • Issue
    7
  • fYear
    1984
  • fDate
    7/1/1984 12:00:00 AM
  • Firstpage
    992
  • Lastpage
    993
  • Abstract
    Results of a study of the helium thyratron for high-power applications are reported. The helium thyratron operates at high voltages and currents, comparable to hydrogen, and, for certain of the conditions studied, recovers faster than hydrogen. These results suggest that helium thyratrons should be seriously considered for high-power applications, such as excimer lasers.
  • Keywords
    Electrodes; Gas lasers; Gases; Helium; Hydrogen; Jitter; Switches; Thyratrons; Vacuum systems; Voltage;
  • fLanguage
    English
  • Journal_Title
    Electron Devices, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9383
  • Type

    jour

  • DOI
    10.1109/T-ED.1984.21644
  • Filename
    1483929