• DocumentCode
    1093683
  • Title

    Improvement of the Voltage Dependence of High-Voltage AC–DC Transfer Differences at the NMIJ

  • Author

    Fujiki, Hiroyuki

  • Author_Institution
    Nat. Inst. of Adv. Ind. Sci. & Technol., Nat. Metrol. Inst. of Japan, Tsukuba
  • Volume
    57
  • Issue
    9
  • fYear
    2008
  • Firstpage
    1992
  • Lastpage
    1997
  • Abstract
    A new AC-DC comparator system of 20-1000 V has been developed at the National Metrology Institute of Japan (NMIJ) for the calibration of ac-dc thermal voltage converters (TVCs), which are used as national ac-dc transfer standards. The ac-dc transfer differences of high-voltage transfer standards were evaluated by a traditional step-up procedure. The voltage dependence of the ac-dc transfer difference was observed in the earlier step-up procedures over 300 V, as reported by the latest international intercomparison. The experimental results for high-voltage TVCs with several different range resistors at the NMIJ suggest that the voltage dependence may primarily be caused by input connectors of range resistors and the change in the resistance value of the resistor and TVC modules due to heating from resistors. This paper describes the voltage dependence improvement of ac-dc transfer differences over 300 V at the NMIJ.
  • Keywords
    AC-DC power convertors; calibration; resistors; AC-DC comparator system; AC-DC thermal voltage converters; National Metrology Institute of Japan; calibration; high-voltage AC-DC transfer differences; international intercomparison; range resistor; voltage 20 V to 1000 V; AC–DC transfer difference; AC??DC transfer difference; ac voltage standard; range resistor; thermal voltage converters (TVCs); voltage dependence;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2008.917256
  • Filename