Extracting a Cardiac Signal From the Extracorporeal Pressure Sensors of a Hemodialysis Machine
Author :
Holmer, Mattias ; Sandberg, Frida ; Solem, Kristian ; Grigonyte, Egle ; Olde, Bo ; Sornmo, Leif
Author_Institution :
Gambro Lundia AB, Lund, Sweden
Volume :
62
Issue :
5
fYear :
2015
fDate :
May-15
Firstpage :
1305
Lastpage :
1315
Abstract :
Although patients undergoing hemodialysis treatment often suffer from cardiovascular disease, monitoring of cardiac rhythm is not performed on a routine basis. Without requiring any extra sensor, this study proposes a method for extracting a cardiac signal from the built-in extracorporeal venous pressure sensor of the hemodialysis machine. The extraction is challenged by the fact that the cardiac component is much weaker than the pressure component caused by the peristaltic blood pump. To further complicate the extraction problem, the cardiac component is difficult to separate when the pump and heart rates coincide. The proposed method estimates a cardiac signal by subtracting an iteratively refined blood pump model signal from the signal measured at the extracorporeal venous pressure sensor. The method was developed based on simulated pressure signals, and evaluated on clinical pressure signals acquired during hemodialysis treatment. The heart rate estimated from the clinical pressure signal was compared to that derived from a photoplethysmographic reference signal, resulting in a difference of 0.07 ± 0.84 beats/min. The accuracy of the heartbeat occurrence times was studied for different strengths of the cardiac component, using both clinical and simulated signals. The results suggest that the accuracy is sufficient for analysis of heart rate and certain arrhythmias.
Keywords :
biomedical equipment; blood; blood pressure measurement; cardiology; diseases; iterative methods; medical signal detection; medical signal processing; patient monitoring; patient treatment; pressure sensors; arrhythmias; built-in extracorporeal venous pressure sensor; cardiac component; cardiac rhythm monitoring; cardiovascular disease; clinical pressure signal acquisition; heart rate analysis; hemodialysis machine; hemodialysis treatment; iterative refined blood pump model signal; peristaltic blood pump; pressure component; simulated pressure signals; Blood; Estimation; Heart beat; Monitoring; Pumps; Sensors; Blood access pressure simulator; Heart rate; blood access pressure simulator; cardiac pressure signal; extracorporeal pressure sensors; fistula; heart rate; hemodialysis;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/TBME.2014.2385964
Filename :
6998042
Link To Document :
بازگشت