• DocumentCode
    1095429
  • Title

    A dosimetric evaluation of the RADPAK using mono-energetic electrons and protons

  • Author

    Adams, L. ; Nickson, R. ; Kelleher, A. ; Millward, D.G. ; Strobel, D.J. ; Czajkowski, D.

  • Author_Institution
    Eur. Space Res. & Technol. Centre, Noordwijk, Netherlands
  • Volume
    43
  • Issue
    3
  • fYear
    1996
  • fDate
    6/1/1996 12:00:00 AM
  • Firstpage
    1014
  • Lastpage
    1017
  • Abstract
    This paper presents the results of an evaluation of the Space Electronics Inc. RADPAK using electron and proton accelerators. `RADFET´ dosimeters were used as test vehicles in conventional and RADPAK packages to allow a direct comparison of absorbed dose with different shielding. Electron results are compared with the AE-8 space spectrum and proton results verified by transport calculations
  • Keywords
    electron beam effects; field effect transistors; proton effects; semiconductor device packaging; semiconductor device testing; shielding; space vehicle electronics; AE-8 space spectrum; RADFET dosimeters; RADPAK; absorbed dose; dosimetric evaluation; mono-energetic electrons; mono-energetic protons; semiconductor device packaging; shielding; space vehicle electronics; test vehicles; transport calculations; Diodes; Dosimetry; Educational institutions; Electronics packaging; Electrons; Proton accelerators; Semiconductor device packaging; Space technology; Testing; Vehicles;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.510749
  • Filename
    510749