DocumentCode
1095831
Title
Variational design of zone plates for the VUV and soft X-ray ranges
Author
Tatchyn, R. ; Csonka, P.L. ; Lindau, I.
Author_Institution
Stanford Synchrotron Radiation Lab. and Stanford Electronics Labs, Stanford Univ., Stanford, CA, USA
Volume
19
Issue
12
fYear
1983
fDate
12/1/1983 12:00:00 AM
Firstpage
1821
Lastpage
1823
Abstract
Many materials become appreciably translucent in the soft X-ray range, making them suitable for use as optical elements. However, since none is Perfectly transparent, it is crucial that optimum design procedures be followed in order to minimize unnecessary optical losses. In this paper we demonstrate such a solution for the ordinary metallic zone plate and compare its performance to some recently proposed configurations which were advanced on the basis of more restricted considerations.
Keywords
Gold materials/devices; Optical components; Optical diffraction; Ultraviolet materials/devices; Variational methods; X-ray imaging; Geometry; Helium; Laboratories; Optical losses; Optical materials; Optical refraction; Optical surface waves; Surface waves; Throughput; X-ray diffraction;
fLanguage
English
Journal_Title
Quantum Electronics, IEEE Journal of
Publisher
ieee
ISSN
0018-9197
Type
jour
DOI
10.1109/JQE.1983.1071812
Filename
1071812
Link To Document