DocumentCode :
1096647
Title :
Evaluation of AC-coupled silicon microstrip detectors and Berkeley SVXD readout with 227 GeV/c pions
Author :
Lambrecht, M. ; Attias, H. ; Barger, K. ; Kalbfleisch, G. ; Kaplan, D. ; Karchin, P. ; Kuehler, J. ; McCliment, E. ; Ross, W. ; Sinnott, J. ; Skubic, P. ; Utku, S.
Author_Institution :
Oklahoma Univ., Norman, OK, USA
Volume :
38
Issue :
2
fYear :
1991
fDate :
4/1/1991 12:00:00 AM
Firstpage :
446
Lastpage :
453
Abstract :
Single-sided and double-sided AC-coupled Si microstrip detectors read out with Berkeley SVX version D VLSI chips have been tested in a 227-GeV/c charged pion beam at Fermilab. Pulse height information, cluster size, and spatial resolution have been studied as functions of incident beam angle. It was found that the experimental spatial resolution agrees with Monte Carlo predictions and that the average pulse height and cluster size increase accordingly with increasing angle of particle incidence from the normal. The results of the beam tests are presented in detail
Keywords :
Monte Carlo methods; meson detection and measurement; semiconductor counters; AC-coupled Si microstrip detectors; Berkeley SVX version D VLSI chips; Berkeley SVXD readout; Monte Carlo; Si; charged pion beam; cluster size; pulse height; spatial resolution; Assembly; Detectors; Mesons; Microstrip; Optical coupling; Semiconductor device measurement; Silicon; Spatial resolution; Strips; Testing;