Title :
Experimental Correlation of the Aging Process of the ADSS Fiber-Optic Cables in ASU´s Environmental Chamber to Field Tests in Bandon, OR
Author :
Al-Ammar, Essam ; Karady, George G. ; Tuominen, Monty W. ; Vermeers, Danna J.
Author_Institution :
King Saud Univ., Riyadh
fDate :
4/1/2008 12:00:00 AM
Abstract :
An environmental chamber has been constructed at Arizona State University to establish a long-term aging test of all-dielectric self-supporting (ADSS) fiber-optic cable. A polymer-jacketed ADSS (track resistant) cable is subjected to UV radiation, salt fog, clean rain, and mechanical tension in the aging chamber. Installed by the Bonneville Power Administration (BPA), a similar track resistant ADSS has been in operation for about eight years, near the Pacific Ocean at Bandon, OR. Accumulated pollution on this ADSS has been measured by BPA on approximately a semiannual basis. In this paper, the aging chamber operation is outlined briefly and two methods of measuring the accumulating pollution level on the ADSS cables in the aging chamber are described. The accumulated pollution levels of both ADSS cables in the chamber and in Bandon, OR, are compared. It is noted that general chamber performance compares favorably to the field data as well as suggesting an approximate chamber-aging rate, about 18:1.
Keywords :
ageing; cable insulation; cable sheathing; optical fibre testing; UV radiation; aging process; all-dielectric self-supporting fiber optic cable; clean rain; environmental chamber; field tests; long-term aging test; mechanical tension; polymer jacketed cable; salt fog; track resistant cable; Aging; all-dielectric self supporting (ADSS); correlation; fiber-optic cable; field; measurements; pollution; transmission line;
Journal_Title :
Power Delivery, IEEE Transactions on
DOI :
10.1109/TPWRD.2008.917676