  • Abstract
    The total dose response of the Analog Devices AD590 is presented for a variety of irradiation test conditions. The parts packaged in flat-packs show very large enhanced low dose rate sensitive (ELDRS) response for unbiased irradiation, starting at about 20 krad, whereas parts packaged in TO-52 cans are not ELDRS. The reason for this package sensitivity appears to be a result of hydrogen trapped in the cavity of the flat-pack package. The responses at 10 mrad/s and 3 mrad/s are essentially the same, indicating that the low dose rate enhancement factor has leveled off below 10 mrad/s. Elevated temperature irradiation at 100degC and 5 rad/s does not simulate the low dose rate response.
  • Keywords
    dosimetry; transducers; Analog Devices AD590 temperature transducer; dose rate enhancement factor; dose rate response; package sensitivity; temperature 100 C; total dose response; Circuits; Cranes; Current density; Hydrogen; Packaging; Resistors; Temperature sensors; Testing; Transducers; Voltage; Dose rate; enhanced low-dose-rate sensitivity; radiation effects; temperature transducer; total ionizing dose;