DocumentCode :
1098960
Title :
Measurement of RF Leakage in Multipin Electrical Connectors
Author :
Schor, F.W.
Author_Institution :
ITT Cannon Electric, Los Angeles, Calif
Issue :
1
fYear :
1968
fDate :
3/1/1968 12:00:00 AM
Firstpage :
135
Lastpage :
141
Abstract :
In the past measurements of connector RFI leakage have evaluated combinations of the connector and cable so that it has been difficult to separate the effects of the different leakage areas. The methods presented here enable the designer first to evaluate the leakage at the interface coupling with a variety of connector characteristics and then, separately, to obtain the cable RF leakage. Thus the effects of the varying parameters of connector design may be determined without being affected by the connecting cable leakage. RFI performance data are presented, covering the range of 150 kHz to 1000 MHz. A description of the measuring technique and its development is also included. A series of recommendations aimed toward reducing RFI leakage in multipin electrical connectors are given.
Keywords :
Area measurement; Cable shielding; Connectors; Current measurement; Electric variables measurement; Electromagnetic measurements; Joining processes; Radio frequency; Radiofrequency interference; Shape measurement;
fLanguage :
English
Journal_Title :
Electromagnetic Compatibility, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9375
Type :
jour
DOI :
10.1109/TEMC.1968.302920
Filename :
4090379
Link To Document :
بازگشت