DocumentCode :
1101216
Title :
New Epstein Frame for Lamination Core Loss Measurements Under High Frequencies and High Flux Densities
Author :
Mthombeni, Tsakani Lotten ; Pillay, Pragasen ; Strnat, Reinhold M W
Author_Institution :
Clarkson Univ., Potsdam
Volume :
22
Issue :
3
fYear :
2007
Firstpage :
614
Lastpage :
620
Abstract :
This paper presents a new Epstein frame optimized for high frequencies and high flux densities. The design philosophy and test results at high power frequencies are presented. The frame achieves high frequency and high flux density performance because of reduced number of turns and reduced number of samples, while using standard 25-cm Epstein samples. Some of its technical advantages over the current Epstein frames and the single sheet testers are less samples´ preparation time and better material representability, respectively. Four lamination types were tested: 0.0250-in (0.64 mm) M36 and cold rolled motor lamination, 0.0184-in (0.47 mm) M19, and 0.0140-in (0.36 mm) M45. The results obtained show good agreement with the core loss data provided by the steel manufacturers measured using the old frames at 200, 300, and 400 Hz. Results at 600 Hz and 1.0 kHz are also presented for the M45 and M19 samples along with the test bench used.
Keywords :
cold rolling; cores; laminations; loss measurement; machine testing; Epstein frame; cold rolled motor lamination; high flux densities; lamination core loss measurements; material representability; steel manufacturers; Brushless DC motors; Core loss; DC motors; Density measurement; Electric motors; Frequency measurement; Lamination; Loss measurement; Reluctance motors; Testing; Core losses; Epstein frame; high flux density; high frequency;
fLanguage :
English
Journal_Title :
Energy Conversion, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8969
Type :
jour
DOI :
10.1109/TEC.2007.895875
Filename :
4292195
Link To Document :
بازگشت