Author :
Ogata, H. ; Ando, T. ; Ito, T. ; Matsui, K. ; Sugimoto, M. ; Kato, T. ; Nakajima, H. ; Nishi, M. ; Isono, T. ; Takahashi, Y. ; Tsuji, H. ; Shimamoto, S. ; Sumiyoshi, Y. ; Osaki, O. ; Fujioka, T. ; Okuno, K.
Abstract :
The Japan Atomic Energy Research Institute (JAERI) has been designing and developing the central solenoid (CS) model coil for International Thermonuclear Experimental Reactor (ITER). The CS model coil is composed of two modules and they will be manufactured by a United States Home Team and a Japanese Home Team. The coil winding method is two-conductors-in-hand and the coil, which has an inner diameter of 1.6 m and an outer diameter of 3.6 m, produces a maximum field of 13 T. The coil will be tested in the JAERI facility. This paper describes the coil design, manufacturing procedure, stress analysis on the winding pack and AC loss analysis
Keywords :
design engineering; electron device manufacture; fusion reactor materials; fusion reactors; manufacturing processes; superconducting coils; superconducting magnets; winding (process); 1.6 m; 13 T; 3.6 m; AC loss analysis; ITER; International Thermonuclear Experimental Reactor; central solenoid model superconducting coil; coil design; coil winding method; manufacturing procedure; stress analysis; two-conductors-in-hand; winding pack; Conductors; Electronic design automation and methodology; Fabrication; Inductors; Insulation; Niobium-tin; Solenoids; Superconducting coils; Testing; Virtual manufacturing;