    The magnets and power supplies of the GSI beam scanning system for heavy ion cancer therapy

  • Author

    Langenbeck, B. ; Breitenberger, G. ; Gaiser, H. ; Klos, F. ; Moritz, G. ; Zweig, K.

  • Author_Institution
    Gesellschaft fur Schwerionenforschung mbH, Darmstadt, Germany
  • Volume
    32
  • Issue
    4
  • fYear
    1996
  • fDate
    7/1/1996 12:00:00 AM
  • Firstpage
    2651
  • Lastpage
    2654
  • Abstract
    The magnets and power supplies of a raster scanning system for a particle therapy facility have been designed and carefully measured after delivery. Well known and proven techniques have been used in construction and production of the laminated window frame magnets and the pulsed power supplies to avoid failures of the system and to assure absolute security of patients during treatment. The scanning interval in both transverse directions is 20 cm. The vertical deflection includes an offset of 20 cm between the undeflected beam and the scanning area to have space for last beam diagnostic purposes just before beginning treatment. The scanning depth is established by varying the energy of the carbon, oxygen, or neon ions to energies up to 550 A MeV
  • Keywords
    biomedical electronics; coils; electromagnets; ion beam applications; ion beams; power supplies to apparatus; pulsed power technology; radiation therapy; 20 cm; GSI beam scanning system; heavy ion cancer therapy; laminated window frame magnets; particle therapy facility; pulsed power supplies; raster scanning system; scanning depth; scanning interval; vertical deflection; Apertures; Cancer; Coils; Conductors; Magnets; Medical treatment; Particle beams; Power supplies; Pulsed power supplies; Structural beams;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.511419
  • Filename