DocumentCode :
1104315
Title :
Use of a Reverberating Enclosure for Measurements of Radiated Power in the Microwave Range
Author :
Corona, Paolo ; Latmiral, Gaetano ; Paolini, Enrico ; Piccioli, Luigi
Author_Institution :
Institute of Electromagnetic Waves, Istituto Universitario Navale, Naples, Italy
Issue :
2
fYear :
1976
fDate :
5/1/1976 12:00:00 AM
Firstpage :
54
Lastpage :
59
Abstract :
A method using a reverberating enclosure for evaluating the radiation of an apparatus in the microwave range (1-18 GHz)is described. The physical performance of the reverberating enclosure has been analyzed by means of a sampling correlator. The method is particularly suitable for measurements of radiated interference from industrial, scientific, and medical (I.S.M.) equipment in terms of power, and to state their compliance with specified limits. Other important applications of the reverberating enclosure may include the measurement of average absorption coefficient of bulk or plate materials and of the behavior of the human body in an EM microwave field.
Keywords :
Correlators; Electromagnetic wave absorption; Interference; Microwave devices; Microwave measurements; Microwave theory and techniques; Particle measurements; Performance analysis; Power measurement; Sampling methods;
fLanguage :
English
Journal_Title :
Electromagnetic Compatibility, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9375
Type :
jour
DOI :
10.1109/TEMC.1976.303466
Filename :
4090955
Link To Document :
بازگشت