DocumentCode :
1104469
Title :
On the Effective Transfer Impedance of Thin Coaxial Cable Shields
Author :
Casey, Kendall F.
Author_Institution :
Department of Electrical Engineering, Kansas State University, Manhattan, KS 66506
Issue :
3
fYear :
1976
Firstpage :
110
Lastpage :
117
Abstract :
It is shown that the effective transfer impedance per unit length of a thin coaxial cable shield is given by Zs h2/Ys, where ZS and Ys are, respectively, the cable´s inductive transfer impedance per unit length and capacitive transfer admittance per unit length, and h is the axial propagation constant. This general result is illustrated by consideration of a specific shield model, the M-filar filamentary helix.
Keywords :
Admittance; Cable shielding; Coaxial cables; Communication cables; Conductors; Equations; Impedance; Propagation constant; Transmission lines; Voltage;
fLanguage :
English
Journal_Title :
Electromagnetic Compatibility, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9375
Type :
jour
DOI :
10.1109/TEMC.1976.303480
Filename :
4090973
Link To Document :
بازگشت