Title :
X-ray Performance Evaluation of the Dexela CMOS APS X-ray Detector Using Monochromatic Synchrotron Radiation in the Mammographic Energy Range
Author :
Konstantinidis, Anastasios C. ; Szafraniec, Magdalena B. ; Rigon, Luigi ; Tromba, Giuliana ; Dreossi, Diego ; Sodini, Nicola ; Liaparinos, Panagiotis F. ; Naday, Steve ; Gunn, Spencer ; McArthur, Alan ; Speller, Robert D. ; Olivo, A.
Author_Institution :
Dept. of Med. Phys. & Bioeng., Univ. Coll. London, London, UK
Abstract :
Digital detectors based on complementary metal-oxide-semiconductors (CMOS) active pixel sensor (APS) technology have been introduced recently in many scientific applications. This work is focused on the X-ray performance evaluation of a novel CMOS APS detector in low energy medical imaging applications using monochromatic synchrotron radiation (i.e., 17-35 keV), which also allows studying how the performance varies with energy. The CMOS sensor was coupled to a Thallium-activated structured cesium iodide (CsI:Tl) scintillator and the detector´s X-ray performance evaluation was carried out in terms of sensitivity, presampling modulation transfer function (pMTF), normalized noise power spectrum (NNPS) and the resulting detective quantum efficiency (DQE). A Monte Carlo simulation was used to validate the experimentally measured low frequency DQE. Finally, the effect of iodine´s secondary generated K-fluorescence X-rays on pMTF and DQE results was evaluated. Good agreement (within 5%) was observed between the Monte Carlo and experimentally measured low frequency DQE results. A CMOS APS detector was characterized for the first time over a wide range of low energies covering the mammographic spectra. The detector´s performance is limited mainly by the detectability of the scintillator. Finally, we show that the current data could be used to calculate the detector´s pMTF, NNPS and DQE for any mammographic spectral shape within the investigated energies.
Keywords :
CMOS image sensors; Monte Carlo methods; X-ray detection; mammography; CMOS active pixel sensor technology; DQE; Dexela CMOS APS X-ray detector technology; K-fluorescence X-rays; Monte Carlo simulation; Thallium activated structured cesium iodide; X-ray performance evaluation; complementary metal-oxide-semiconductors; detectability; detective quantum efficiency; digital detectors; mammographic energy range; mammographic spectral shape; medical imaging applications; monochromatic synchrotron radiation; normalized noise power spectrum; presampling modulation transfer function; scintillator; Biomedical imaging; CMOS integrated circuits; Detectors; Noise; Photonics; X-ray detectors; X-ray imaging; Complementary metal-oxide-semiconductor (CMOS); digital mammography; image quality; synchrotron radiation;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.2013.2276123