• DocumentCode
    1105031
  • Title

    Worst-Case Suppressor Testing Methods-The Minimum Attenuation Concept

  • Author

    Jarvis, M.L. ; Thomson, J.M.

  • Author_Institution
    Ministry of Defence (Procurement Executive), London WC2, England, U.K.
  • Issue
    2
  • fYear
    1977
  • fDate
    5/1/1977 12:00:00 AM
  • Firstpage
    99
  • Lastpage
    100
  • Abstract
    A recent paper by H. M. Schlicke [1] proposed a worstcase power-line filter testing method. An alternative method, the minimum attenuation concept, also under consideration by CISPR, is outlined.
  • Keywords
    Attenuation measurement; Current measurement; Electromagnetic measurements; Filters; IEC standards; Impedance measurement; Radio frequency; Signal generators; Testing; Voltage; Minimum attenuation; power-line filter testing;
  • fLanguage
    English
  • Journal_Title
    Electromagnetic Compatibility, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9375
  • Type

    jour

  • DOI
    10.1109/TEMC.1977.303554
  • Filename
    4091032