  • Abstract
    Quench observation using quench antennas is now being performed routinely on RHIC dipole and quadrupole magnets. Recently, a quench antenna was used on a RHIC IR magnet which is heavily instrumented with voltage taps. It was confirmed that the signals detected in the antenna coils do not contradict the voltage tap signals. The antenna also detects a sign of mechanical disturbance which could be related to a training quench. This paper summarizes signals detected in the antenna and discusses possible causes of these signals
  • Keywords
    accelerator magnets; antenna arrays; superconducting device testing; superconducting magnets; RHIC IR quadrupole magnet; coil signal; mechanical disturbance; quench antenna measurements; training quench; voltage tap signal; Apertures; Coils; Collaborative work; Fluctuations; Magnetic field measurement; Magnets; Postal services; Testing; Vibrations; Voltage;