DocumentCode :
1108368
Title :
The effect of coil parameters on the distribution of steep-fronted surges in machine windings
Author :
Guardado, J.L. ; Cornick, K.J.
Author_Institution :
IIE, Cuernavaca, Mexico
Volume :
7
Issue :
3
fYear :
1992
fDate :
9/1/1992 12:00:00 AM
Firstpage :
552
Lastpage :
559
Abstract :
The authors identify the coil parameters that are of importance, when assessing interturn voltages produced by steep-fronted transients. The studies are based on a multiconductor transmission line computer model of a machine winding energized by a simple ramp function. Variations in interturn voltages produced by changes in insulation thickness, insulation permittivity, turn geometry, coil length and number of turns are examined and certain guidelines for avoiding high interturn voltages are evaluated. An application study is included to show how interturn voltages can be significantly reduced by applying these guidelines
Keywords :
electric machine analysis computing; electric machines; machine insulation; machine theory; machine windings; surges; transients; transmission line theory; coil parameters; control system analysis computing; insulation; interturn voltages; machine windings; model; multiconductor transmission line; ramp function; surges; transients; Application software; Coils; Geometry; Guidelines; Insulation; Machine windings; Multiconductor transmission lines; Permittivity; Power system transients; Voltage;
fLanguage :
English
Journal_Title :
Energy Conversion, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8969
Type :
jour
DOI :
10.1109/60.148578
Filename :
148578
Link To Document :