• DocumentCode
    1108524
  • Title

    Impulse Strength of High Voltage Motor Coil Turn Insulation

  • Author

    Gupta, B.K. ; Kurtz, M. ; Stone, G.C. ; Sharma, D.K.

  • Author_Institution
    Ontario Hydro
  • Issue
    4
  • fYear
    1986
  • Firstpage
    130
  • Lastpage
    134
  • Abstract
    Breakdown of the turn insulation in large ac motors eventually leads to the failure of the stator winding. The turn insulation can fail if the motor coils are subjected to steep-fronted surges. The impulse strength of the turn insulation was determined for fifty-three typical coils procured from different manufacturers and tested singly in air. The coils had six different insulation systems and their specifications (voltage, power, size, turns, strands etc) cover a very wide range. Most coils were found to have an impulse strength exceeding 5 times peak line-to-ground voltage (5 pu).
  • Keywords
    AC motors; Breakdown voltage; Cable insulation; Coils; Glass manufacturing; Impulse testing; Insulation testing; Pulp manufacturing; System testing; Wire;
  • fLanguage
    English
  • Journal_Title
    Energy Conversion, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8969
  • Type

    jour

  • DOI
    10.1109/TEC.1986.4765786
  • Filename
    4765786