DocumentCode :
1108627
Title :
Grid-Connected Photovoltaic System With Power Factor Correction
Author :
Lo, Yu-Kang ; Lee, Ting-Peng ; Wu, Kuan-Hung
Author_Institution :
Dept. of Electron. Eng., Nat. Taiwan Univ. of Sci. & Technol., Taipei
Volume :
55
Issue :
5
fYear :
2008
fDate :
5/1/2008 12:00:00 AM
Firstpage :
2224
Lastpage :
2227
Abstract :
A combined grid-connection/power-factor-correction technique for a photovoltaic (PV) system is proposed in this letter. A maximum power point tracking dc/dc converter served as a charger for the battery bank. A bidirectional inverter is applied as a generator/discharger during daytime, supplying power to the load. The inverter can also be used as a charger to maintain the minimum required voltage level of the batteries when the PV power is insufficient. Experiments on a 1-kW PV system show satisfactory results of the power management and the unity power factor at the utility side.
Keywords :
DC-DC power convertors; battery chargers; photovoltaic power systems; power factor correction; power system interconnection; battery bank charger; bidirectional inverter; grid-connected photovoltaic system; maximum power point tracking dc/dc converter; power 1 kW; power factor correction; power management; Grid connection; grid-connection; photovoltaic (PV) system; photovoltaic system; power factor (PF) correction; power factor correction;
fLanguage :
English
Journal_Title :
Industrial Electronics, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0046
Type :
jour
DOI :
10.1109/TIE.2008.921204
Filename :
4475435