DocumentCode
1108658
Title
Collider dipole magnet field angle measurement
Author
Albert, G.W. ; Pidcoe, S.V. ; Peck, S.D. ; Bailey, AndR E.
Author_Institution
Gen. Dynamics Space Syst. Div., San Diego, CA, USA
Volume
27
Issue
2
fYear
1991
fDate
3/1/1991 12:00:00 AM
Firstpage
2012
Lastpage
2015
Abstract
Methods and devices for measuring the prototype Superconducting Super Collider (SSC) dipole magnetic field angle with respect to a vertical reference are discussed. An internal research and development project was conducted to develop a low-cost device for production measurement of the SSC dipole field verticality. The system employs Hall probes, a level sensor, and precision electronics interfaced to a personal computer to perform this critical measurement at discrete points along the magnet beam axis. Specification, component selection, mechanical and electrical design, calibration, and test results are presented
Keywords
Hall effect transducers; beam handling equipment; calibration; computerised instrumentation; magnetic field measurement; microcomputer applications; proton accelerators; storage rings; superconducting magnets; synchrotrons; Hall probes; PC interfaced; Superconducting Super Collider; calibration; component selection; dipole field verticality; dipole magnet field angle measurement; electrical design; level sensor; low-cost device; mechanical design; precision electronics; production measurement; specification; Goniometers; Hall effect devices; Level control; Magnetic field measurement; Microcomputers; Performance evaluation; Production; Prototypes; Research and development; Superconducting magnets;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/20.133601
Filename
133601
Link To Document