DocumentCode :
1109100
Title :
Non-Simultaneous Reclosing Air-Gap Transient Torque of Induction Motor: Part I, Analysis and Computation Logic
Author :
Htsui, John S.C.
Author_Institution :
Heavy Industry Motor Division, Westinghouse Electric Corporation, Round Rock, Texas
Issue :
2
fYear :
1987
fDate :
6/1/1987 12:00:00 AM
Firstpage :
269
Lastpage :
275
Abstract :
Non-simultaneous reclosing of an induction motor involves three transient steps: the switching off, the reclosing of two of the three switch poles, and the reclosing of the third pole. Each step is initiated and superimposed successively to give a complete transient picture. The analysis and the computation logic are given in this part. The application of the analytical results and the discussion of the American National Standard, ANSI C50.41, for reclosing of induction motors, are given in Part II.
Keywords :
ANSI standards; Air gaps; Capacitors; Circuits; Induction motors; Logic; Switches; Torque; Transient analysis; Voltage;
fLanguage :
English
Journal_Title :
Energy Conversion, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8969
Type :
jour
DOI :
10.1109/TEC.1987.4765841
Filename :
4765841
Link To Document :
بازگشت