DocumentCode
1110978
Title
In Situ Measurement of UHF Wearable Antenna Radiation Efficiency Using a Reverberation Chamber
Author
Conway, Gareth A. ; Scanlon, William G. ; Orlenius, Charlie ; Walker, Chris
Author_Institution
Queen´´s Univ., Belfast
Volume
7
fYear
2008
fDate
6/30/1905 12:00:00 AM
Firstpage
271
Lastpage
274
Abstract
The radiation efficiency and resonance frequency of five compact antennas worn by nine individual test subjects was measured at 2.45 GHz in a reverberation chamber. The results show that, despite significant differences in body mass, wearable antenna radiation efficiency had a standard deviation less than 0.6 dB and the resonance frequency shift was less than 1% between test subjects. Variability in the radiation efficiency and resonance frequency shift between antennas was largely dependant on body tissue coupling which is related to both antenna geometry and radiation characteristics. The reverberation chamber measurements were validated using a synthetic tissue phantom and compared with results obtained in a spherical near field chamber and finite-difference time-domain (FDTD) simulation.
Keywords
UHF antennas; antenna radiation patterns; finite difference time-domain analysis; FDTD; UHF wearable antenna radiation efficiency; antenna geometry; finite-difference time-domain simulation; frequency 2.45 GHz; in situ measurement; resonance frequency shift; reverberation chamber; Bodyworn antennas; on-body communications; wearable antenna radiation efficiency;
fLanguage
English
Journal_Title
Antennas and Wireless Propagation Letters, IEEE
Publisher
ieee
ISSN
1536-1225
Type
jour
DOI
10.1109/LAWP.2008.920753
Filename
4476082
Link To Document