• DocumentCode
    1110978
  • Title

    In Situ Measurement of UHF Wearable Antenna Radiation Efficiency Using a Reverberation Chamber

  • Author

    Conway, Gareth A. ; Scanlon, William G. ; Orlenius, Charlie ; Walker, Chris

  • Author_Institution
    Queen´´s Univ., Belfast
  • Volume
    7
  • fYear
    2008
  • fDate
    6/30/1905 12:00:00 AM
  • Firstpage
    271
  • Lastpage
    274
  • Abstract
    The radiation efficiency and resonance frequency of five compact antennas worn by nine individual test subjects was measured at 2.45 GHz in a reverberation chamber. The results show that, despite significant differences in body mass, wearable antenna radiation efficiency had a standard deviation less than 0.6 dB and the resonance frequency shift was less than 1% between test subjects. Variability in the radiation efficiency and resonance frequency shift between antennas was largely dependant on body tissue coupling which is related to both antenna geometry and radiation characteristics. The reverberation chamber measurements were validated using a synthetic tissue phantom and compared with results obtained in a spherical near field chamber and finite-difference time-domain (FDTD) simulation.
  • Keywords
    UHF antennas; antenna radiation patterns; finite difference time-domain analysis; FDTD; UHF wearable antenna radiation efficiency; antenna geometry; finite-difference time-domain simulation; frequency 2.45 GHz; in situ measurement; resonance frequency shift; reverberation chamber; Bodyworn antennas; on-body communications; wearable antenna radiation efficiency;
  • fLanguage
    English
  • Journal_Title
    Antennas and Wireless Propagation Letters, IEEE
  • Publisher
    ieee
  • ISSN
    1536-1225
  • Type

    jour

  • DOI
    10.1109/LAWP.2008.920753
  • Filename
    4476082