DocumentCode :
1111291
Title :
Correlation Between the Quasi-Peak Value of Noise Measured by Aiya´s Noise Meter and the rms Value Measured by the ARN-2 Recorder
Author :
Agarwala, R.A.
Author_Institution :
Department of Electronics and Communications ions Engineering, Regional Engineering College, Kurukshetra 132 119, India.
Issue :
4
fYear :
1983
Firstpage :
389
Lastpage :
395
Abstract :
The parameters measured by the two methods are well correlated for the burst form of noise. The median value of the conversion ratio could be stated as 10 dB with a standard deviation of 4 dB. The value is quantity-addressed and is fairly valid generally. For background noise, the two parameters are practically uncor-related. There is a likelihood for the measurements recorded by the ARN-2 recorder to be contaminated.
Keywords :
Atmospheric measurements; Background noise; Electromagnetic measurements; Frequency measurement; NIST; Noise level; Noise measurement; Pollution measurement; Reliability engineering; Time measurement; APD; Atmosphere noise; burst level; conversion ratio; rms level;
fLanguage :
English
Journal_Title :
Electromagnetic Compatibility, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9375
Type :
jour
DOI :
10.1109/TEMC.1983.304127
Filename :
4091675