Title :
A Simple Interior Decomposition Model: Its Development And Application
Author :
Kunz, K.S. ; Breakall, J.K. ; Ludwigsen, A.P.
Author_Institution :
Electrical Engineering Department, Pennsylvania State University, University Park, PA.
Abstract :
A simple interior decomposition model composed of the product of two terms, a shielding-effectiveness term and a coupling- effectiveness term, has been developed that bounds the measured wire responses within a simple generic test object. A variety of modest to strong perturbations to the test object geometry and composition changed the response trend downward by at most 12 dB and typically only by 3-6 dB. Thus the model, called shielding effectiveness à coupling effectiveness (SEXCE), serves as a reasonable characterization of a broad range of generic geometries. It is useful in understanding the interior coupling response behavior and can be used as a predictive tool.
Keywords :
Apertures; EMP radiation effects; Electromagnetic coupling; Engine cylinders; Frequency; Geometry; Laboratories; Pluto; Testing; Wire; coupling effectiveness; shielded cable model; shielding effectiveness;
Journal_Title :
Electromagnetic Compatibility, IEEE Transactions on
DOI :
10.1109/TEMC.1987.304327