• DocumentCode
    1112944
  • Title

    Calculation of Internal Fault Currents in Synchronous Machines

  • Author

    Kinitsky, V.A.

  • Author_Institution
    Drexel Institute of Technology, Philadelphia, Pa.
  • Volume
    84
  • Issue
    5
  • fYear
    1965
  • fDate
    5/1/1965 12:00:00 AM
  • Firstpage
    381
  • Lastpage
    389
  • Abstract
    An internal fault in the armature winding of a synchronous machine occurs at the breakdown of either the minor insulation (turn-to-turn fault) or the major insulation (phase-to-ground fault). The faulty synchronous machine is represented by an equivalent circuit in three symmetrical components which can be connected to the corresponding network. The fault currents can be calculated from the obtained equivalent network. The calculation of internal fault currents has been programmed for the IBM 7090 digital computer, and the calculated values have been compared with the experimental results.
  • Keywords
    Circuit faults; Computer science; Equivalent circuits; Fault currents; Frequency; Insulation; Machine windings; Magnetic field measurement; Synchronous machines; Synchronous motors;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1965.4766209
  • Filename
    4766209