Title :
Simulated Service Aging Tests of Insulating Oils in Transformers
Author :
Adler, H.A. ; Cosgrove, M.F.
Author_Institution :
Commonwealth Edison Company, Chicago, Ill.
Abstract :
Five different oxidation-inhibited oils and one non-inhibited oil were subjected to more than ten years of simulated service aging tests in 10-kVA transformers. The oils were aged in six conservator-type and four sealed gas-blanketed transformers. The purpose of these studies was to determine the performance of these oils in oxidation-protected transformers. All the oils remained serviceable throughout the 10-year aging period, but showed marked differences in quality in the final test period during which six of the transformers were opened and operated as free-breathing transformers.
Keywords :
Aging; Corona; Electron tubes; Instruments; Oil insulation; Petroleum; Power transformer insulation; Power transformers; Testing; Voltmeters;
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
DOI :
10.1109/TPAS.1965.4766240