DocumentCode :
1113532
Title :
A test facility for 200 kA SMES/ETM conductors
Author :
Zeigler, J. ; Colvin, J. ; Huson, R. ; Rocha, R. ; Shotzman, G. ; Michels, P. ; Peck, S.
Author_Institution :
Texas Accel. Center, Woodlands, TX, USA
Volume :
27
Issue :
2
fYear :
1991
fDate :
3/1/1991 12:00:00 AM
Firstpage :
2395
Lastpage :
2398
Abstract :
The test facility and the procedures used to characterize two full-scale copper-stabilized cable-in-conduit superconductors are described. The critical current at 1.8 K was 280 kA at a total field of 5.8 T, 260 kA at 6.4 T, and 215 kA at 7.4 T. The stability margin at 200 kA and 4 to 5 T was 70 to 80 mJ/cm3 of metal. No significant performance degradation was observed after more than 600 load cycles
Keywords :
cable testing; critical currents; superconducting cables; test facilities; 1.8 K; 200 to 280 kA; 4 to 7.4 T; SMES/ETM conductors; cable-in-conduit superconductors; critical current; stability margin; superconducting magnetic energy storage; test facility; Conductors; Helium; Life estimation; Magnetic field measurement; Power transformer insulation; Reservoirs; Samarium; Superconducting magnets; Test facilities; Testing;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/20.133701