• DocumentCode
    1115198
  • Title

    Sensitivity of the balanced Josephson-junction comparator

  • Author

    Filippov, T.V. ; Kornev, V.K.

  • Author_Institution
    Dept. of Phys., Moscow State Univ., USSR
  • Volume
    27
  • Issue
    2
  • fYear
    1991
  • fDate
    3/1/1991 12:00:00 AM
  • Firstpage
    2452
  • Lastpage
    2455
  • Abstract
    The sensitivity of a balanced comparator composed of two overdamped Josephson junctions fed by single flux pulses is calculated, taking into account both thermal and quantum fluctuations. The results of the analysis are compared with those of recent experiments. Ultimate resolution of the balanced comparator with feasible junction parameters is estimated to be as high as ~50 pA/Hz1/2 at 4 K and ~10 pA/Hz1/2 at T→0 K. Performance limits of the device are compared with those of its single-junction counterpart
  • Keywords
    Josephson effect; comparators (circuits); sensitivity analysis; superconducting junction devices; Josephson-junction; balanced comparator; overdamped junctions; quantum fluctuations; sensitivity; single flux pulses; thermal fluctuations; Artificial intelligence; Circuits; Current measurement; Fluctuations; Josephson effect; Josephson junctions; Parameter estimation; Physics; Potential energy; Smoothing methods;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.133715
  • Filename