DocumentCode :
1117122
Title :
Power Line Communication in Medium Voltage Systems: Characterization of MV Cables
Author :
Cataliotti, Antonio ; Daidone, Alfredo ; Tinè, Giovanni
Author_Institution :
Dipt. di Ing. Elettr., Elettron. e delle Telecomun., Univ. di Palermo, Palermo
Volume :
23
Issue :
4
fYear :
2008
Firstpage :
1896
Lastpage :
1902
Abstract :
The aim of this paper is to illustrate the development of a theoretical and experimental study on the characterization of medium voltage (MV) cables in the frequency range 25-200 kHz. Two transmission line configurations, line-ground and line-line, were considered in order to evaluate the main parameters, such as the characteristic impedance and the attenuation constant alpha. A simplified model of the line-ground configuration is proposed which allows one to evaluate the characteristic impedance and the attenuation constant by means of geometrical dimensions. The model was verified by experimental measurements on commonly used MV cables, RG7H1R, with an aluminium core of different sections, 95 mm2 and 185 mm2. Moreover, the experimental tests were carried out for the line-line configuration.
Keywords :
carrier transmission on power lines; power cables; RG7H1R; aluminium core; attenuation constant; characteristic impedance; frequency 25 kHz to 200 kHz; geometrical dimension; line-ground configuration; line-line configuration; medium voltage cables; medium voltage systems; power line communication; Attenuation constant; characteristic impedance; medium voltage cables; power line communication; power system communication;
fLanguage :
English
Journal_Title :
Power Delivery, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8977
Type :
jour
DOI :
10.1109/TPWRD.2008.919048
Filename :
4480134
Link To Document :
بازگشت