Title :
Performance of interior-type permanent-magnet alternator
Author_Institution :
Dept. of Electr. Eng. & Electron., Univ. of Manchester Inst. of Sci. & Technol., UK
fDate :
7/1/1994 12:00:00 AM
Abstract :
Theoretical analysis of an isolated, interior-type permanent magnet alternator feeding a resistive load shows how inverse saliency causes output voltage to rise as load is increased. Computations and practical tests illustrate the influence of machine parameters, including quadrature-axis saturation, upon performance
Keywords :
alternators; load (electric); machine testing; machine theory; permanent magnet machines; interior-type permanent magnet alternator; isolat; load; machine parameters; output voltage; performance; quadrature-axis saturation; resistive load;
Journal_Title :
Electric Power Applications, IEE Proceedings -
DOI :
10.1049/ip-epa:19941207