DocumentCode :
1120944
Title :
Pulse-grouping control method for high-power-density DC=DC converters
Author :
Lee, J.Y.
Author_Institution :
Dankook Univ., Chungnam
Volume :
43
Issue :
19
fYear :
2007
Firstpage :
1048
Lastpage :
1049
Abstract :
The proposed method offers an improved DC/DC converter scheme to increase power density. It is based on half-bridge topology with a newly introduced pulse-grouping control method, which helps to reduce the transformer size and the volume of semiconductor devices, maintaining high efficiency. Test results with 85 W (18.5 V/4.6 A) design shows that the measured efficiency is 93.5% with power density of 36 W/in3.
Keywords :
DC-DC power convertors; bridge circuits; network topology; semiconductor devices; transformers; current 4.6 A; half-bridge topology; high-power-density DC-DC converters; power 85 W; power density; pulse-grouping control method; semiconductor devices; transformer size; voltage 18.5 V;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el:20071046
Filename :
4302820
Link To Document :
بازگشت