Title :
Multikilometer lengths of 3.5-GPa (500 ksi) prooftested fiber
Author :
DiMarcello, Frank V. ; Brownlow, Darryl L. ; Huff, Richard G. ; Hart, Arthur C., Jr.
Author_Institution :
AT&T Bell Laboratories, Murray Hill, NJ, USA
fDate :
10/1/1985 12:00:00 AM
Abstract :
Approximately 70 km of fibers were drawn from synthetic silica rods and prooftested at four stresses between 1.4 GPa (200 ksi) and 3.5 GPa (500 ksi). The longest lengths achieved were 17.3 km passing 1.4 GPa (200 ksi), 13.4 km passing both 2.1 GPa (300 ksi) and 2.8 GPa (400 ksi), and 9.3 km passing 3.5 GPa (500 ksi). Tensile tests comparing fibers previously prooftested at 1.4 GPa (200 ksi) with those tested through 3.5 GPa (500 ksi) show no detectable degradation due to the high-strength prooftesting.
Keywords :
Optical fiber testing; Degradation; Oceans; Optical fiber cables; Optical fiber testing; Optical fibers; Preforms; Production; Silicon compounds; Surface cracks; Tensile stress;
Journal_Title :
Lightwave Technology, Journal of
DOI :
10.1109/JLT.1985.1074314