DocumentCode :
1123509
Title :
Rapid computation of LROC figures of merit using numerical observers (for SPECT/PET reconstruction)
Author :
Khurd, Parmeshwar ; Gindi, Gene
Author_Institution :
Dept. of Electr. & Comput. Eng., State Univ. of New York Stony Brook, NY, USA
Volume :
52
Issue :
3
fYear :
2005
fDate :
6/1/2005 12:00:00 AM
Firstpage :
618
Lastpage :
626
Abstract :
The assessment of positron emission tomography (PET) and single photon emission computed tomography (SPECT) image reconstructions by image quality metrics is typically time consuming, even if methods employing model observers and samples of reconstructions are used to replace human testing. We consider a detection task where the background is known exactly and the signal is known except for location. We develop theoretical formulas to rapidly evaluate two relevant figures of merit: the area under the localization receiver operating characteristic (LROC) curve and the probability of correct localization. The formulas can accommodate different forms of model observer. The theory hinges on the fact that we are able to rapidly compute the mean and covariance of the reconstruction. For four forms of model observer, the theoretical expressions are validated by Monte Carlo studies for the case of MAP (maximum a posteriori) reconstruction. The theory method affords a 102-103 speedup relative to methods in which model observers are applied to sample reconstructions.
Keywords :
Monte Carlo methods; image reconstruction; medical image processing; positron emission tomography; single photon emission computed tomography; Monte Carlo studies; human testing; image quality metrics; image reconstruction; localization receiver operating characteristic; maximum aposteriori reconstruction; positron emission tomography; single photon emission computed tomography; Electrical capacitance tomography; Humans; Image quality; Image reconstruction; Lesions; Magneto electrical resistivity imaging technique; Positron emission tomography; Reconstruction algorithms; Single photon emission computed tomography; Testing; Image quality; localization receiver operating characteristic (LROC); maximum a posteriori (MAP) reconstruction; model observer; positron emission tomography (PET); single photon emission computed tomography (SPECT);
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2005.851458
Filename :
1487691
Link To Document :
بازگشت