• DocumentCode
    1125572
  • Title

    Temporal aberrations due to misalignments of a stretcher-compressor system and compensation

  • Author

    Fiorini, C. ; Sauteret, C. ; Rouyer, C. ; Blanchot, N. ; Seznec, S. ; Migus, A.

  • Author_Institution
    Commissariat a la Energie Atomique, Centre d´´Etudes de Limeil-Valenton, Villeneuve St. Georges, France
  • Volume
    30
  • Issue
    7
  • fYear
    1994
  • fDate
    7/1/1994 12:00:00 AM
  • Firstpage
    1662
  • Lastpage
    1670
  • Abstract
    Sensitivity of alignment is one of the major issues in the stretcher-compressor devices used for chirped pulse amplification. In this paper we discuss the temporal aberrations induced by the different kinds of misalignments of the gratings and we emphasize the importance of spatially transverse effects. We discuss simple criteria for minimizing these faults. Finally, we introduce the basic principles of self-compensation and present such a set-up based on symmetry considerations
  • Keywords
    aberrations; diffraction gratings; high-speed optical techniques; chirped pulse amplification; compensation; grating misalignment; self-compensation; spatially transverse effects; stretcher-compressor system; symmetry; temporal aberrations; Chirp; Crystals; Glass; Gratings; Optical distortion; Optical pulses; Plasma density; Pulse amplifiers; Pulse compression methods; Ultrafast optics;
  • fLanguage
    English
  • Journal_Title
    Quantum Electronics, IEEE Journal of
  • Publisher
    ieee
  • ISSN
    0018-9197
  • Type

    jour

  • DOI
    10.1109/3.299499
  • Filename
    299499