DocumentCode :
1125572
Title :
Temporal aberrations due to misalignments of a stretcher-compressor system and compensation
Author :
Fiorini, C. ; Sauteret, C. ; Rouyer, C. ; Blanchot, N. ; Seznec, S. ; Migus, A.
Author_Institution :
Commissariat a la Energie Atomique, Centre d´´Etudes de Limeil-Valenton, Villeneuve St. Georges, France
Volume :
30
Issue :
7
fYear :
1994
fDate :
7/1/1994 12:00:00 AM
Firstpage :
1662
Lastpage :
1670
Abstract :
Sensitivity of alignment is one of the major issues in the stretcher-compressor devices used for chirped pulse amplification. In this paper we discuss the temporal aberrations induced by the different kinds of misalignments of the gratings and we emphasize the importance of spatially transverse effects. We discuss simple criteria for minimizing these faults. Finally, we introduce the basic principles of self-compensation and present such a set-up based on symmetry considerations
Keywords :
aberrations; diffraction gratings; high-speed optical techniques; chirped pulse amplification; compensation; grating misalignment; self-compensation; spatially transverse effects; stretcher-compressor system; symmetry; temporal aberrations; Chirp; Crystals; Glass; Gratings; Optical distortion; Optical pulses; Plasma density; Pulse amplifiers; Pulse compression methods; Ultrafast optics;
fLanguage :
English
Journal_Title :
Quantum Electronics, IEEE Journal of
Publisher :
ieee
ISSN :
0018-9197
Type :
jour
DOI :
10.1109/3.299499
Filename :
299499
Link To Document :
بازگشت