• DocumentCode
    112876
  • Title

    A 180-Vpp Integrated Linear Amplifier for Ultrasonic Imaging Applications in a High-Voltage CMOS SOI Technology

  • Author

    Kexu Sun ; Zheng Gao ; Ping Gui ; Rui Wang ; Oguzman, Ismail ; Xiaochen Xu ; Vasanth, Karthik ; Qifa Zhou ; Shung, K. Kirk

  • Author_Institution
    Dept. of Electr. Eng., Southern Methodist Univ., Dallas, TX, USA
  • Volume
    62
  • Issue
    2
  • fYear
    2015
  • fDate
    Feb. 2015
  • Firstpage
    149
  • Lastpage
    153
  • Abstract
    This brief presents a monolithically integrated fully differential linear HV amplifier as the driver of an ultrasonic transducer. The linear amplifier is capable of transmitting HV arbitrary signals with a very low harmonic distortion, which is suitable for tissue harmonic imaging and other ultrasonic modes for enhanced imaging quality. The amplifier is designed and implemented using the 0.7- μm CMOS silicon-on-insulator process with 120-V devices. The amplifier, when driving a load of 300 pF in parallel with 100 Ω, is capable of transmitting a sine-wave signal with a frequency of up to 4.4 MHz, a maximum signal swing of 180 Vpp, and a second-order harmonic distortion (HD2) of -56 dBc but only dissipating an average power of 62 mW with a 0.1% duty cycle.
  • Keywords
    CMOS analogue integrated circuits; differential amplifiers; harmonic distortion; integrated circuit design; silicon-on-insulator; ultrasonic imaging; ultrasonic transducers; capacitance 300 pF; driver; duty cycle; enhanced imaging quality; high-voltage CMOS SOI technology; integrated linear amplifier; monolithically integrated fully differential linear HV amplifier; resistance 100 ohm; second-order harmonic distortion; silicon-on-insulator; sine-wave signal; size 0.7 mum; tissue harmonic imaging; transmitting HV arbitrary signals; ultrasonic imaging applications; ultrasonic transducer; voltage 120 V; voltage 180 V; Acoustics; Bandwidth; Imaging; Transducers; Transistors; Transmitters; Ultrasonic imaging; HD2; High voltage (HV); Linear amplifier; THD; Tissue Harmonic Imaging, voltage swing; linear amplifier; second-order harmonic distortion (HD2); tissue harmonic imaging (THI); total harmonic distortion (THD); ultrasonic imaging; ultrasonic imaging, high voltage; voltage swing;
  • fLanguage
    English
  • Journal_Title
    Circuits and Systems II: Express Briefs, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1549-7747
  • Type

    jour

  • DOI
    10.1109/TCSII.2014.2387687
  • Filename
    7001209