DocumentCode
1130267
Title
Quantification of small cerebral ventricular volume changes in treated growth hormone patients using nonrigid registration
Author
Holden, Mark ; Schnabel, Julia A. ; Hill, Derek L G
Author_Institution
Dept. of Radiol. Sci. & Med. Eng., King´´s Coll. London, UK
Volume
21
Issue
10
fYear
2002
Firstpage
1292
Lastpage
1301
Abstract
Nonrigid registration can automatically quantify small changes in volume of anatomical structures over time by means of segmentation propagation. Here, we use a nonrigid registration algorithm based on optimising normalized mutual information to quantify small changes in brain ventricle volume in magnetic resonance (MR) images of a group of five patients treated with growth hormone replacement therapy and a control group of six volunteers. The lateral ventricles are segmented from each subject image by registering with the brainweb image which has this structure delineated. The mean (standard deviation) volume change measurements are 1.09 (0.73) cm3 for the patient group and 0.08 (0.62) cm3 for the volunteer group; this difference is statistically significant at the 1% level. We validate our volume measurements by determining the precision from three consecutive scans of five volunteers and also comparing the measurements to previously published volume change estimates obtained by visual inspection of difference images. Results demonstrate a precision of σ ≤ 0.52 cm3 (n = 5) and a rank correlation coefficient with assessed difference images of ρ = 0.7 (n = 11). To determine the level of shape correspondence we manually segmented subject´s ventricles and compared them to the propagations using a voxel overlap similarity index, this gave a mean similarity index of 0.81 (n = 7).
Keywords
biomedical MRI; brain; image registration; image segmentation; medical image processing; patient treatment; splines (mathematics); volume measurement; brainweb image; difference images; growth hormone treated patients; magnetic resonance imaging; medical diagnostic imaging; nonrigid registration algorithm; optimising normalized mutual information; rank correlation coefficient; segmentation propagation; shape correspondence level; similarity index; small cerebral ventricular volume changes quantification; small changes quantification; structure delineation; visual inspection; volunteers; voxel overlap similarity; Anatomical structure; Biochemistry; Image segmentation; Inspection; Magnetic resonance; Measurement standards; Medical treatment; Mutual information; Shape; Volume measurement; Algorithms; Anatomy, Cross-Sectional; Cerebral Ventricles; Dwarfism, Pituitary; Hormone Replacement Therapy; Human Growth Hormone; Humans; Image Interpretation, Computer-Assisted; Imaging, Three-Dimensional; Magnetic Resonance Imaging; Microbial Sensitivity Tests; Observer Variation; Subtraction Technique;
fLanguage
English
Journal_Title
Medical Imaging, IEEE Transactions on
Publisher
ieee
ISSN
0278-0062
Type
jour
DOI
10.1109/TMI.2002.806281
Filename
1174107
Link To Document