X-ray computed tomography methods for in vivo evaluation of local drug release systems
Author :
Salem, Kyle A. ; Szymanski-Exner, Agata ; Lazebnik, Roee S. ; Breen, Michael S. ; Gao, Jinming ; Wilson, David L.
Author_Institution :
Dept. of Biomed. Eng., Case Western Reserve Univ., Cleveland, OH, USA
Volume :
21
Issue :
10
fYear :
2002
Firstpage :
1310
Lastpage :
1316
Abstract :
Recent advances in drug delivery techniques have necessitated the development of tools for in vivo monitoring of drug distributions. Gamma emission imaging and magnetic resonance imaging suffer from problems of resolution and sensitivity, respectively. We propose that the combination of X-ray CT imaging and image analysis techniques provides an excellent method for the evaluation of the transport of platinum-containing drugs from a localized, controlled release source. We correlated local carboplatin concentration with CT intensity, producing a linear relationship with a sensitivity of 62.6 μg/mL per Hounsfield unit. As an example application, we evaluated the differences in drug transport properties between normal and ablated rabbit liver from implanted polymer millirods. The use of three-dimensional visualization provided a method of evaluating the placement of the drug delivery device in relation to the surrounding anatomy, and registration and reformatting allowed the accurate comparison of the sequence of temporal CT volumes acquired over a period of 24 h. Taking averages over radial lines extending away from the center of the implanted millirods and integrating over clinically appropriate regions, yielded information about drug release from the millirod and transport in biological tissues. Comparing implants in normal and ablated tissues, we found that ablation prior to millirod implantation greatly decreased the loss of drug from the immediate area, resulting in a higher average dose to the surrounding tissue. This work shows that X-ray CT imaging is a useful technique for the in vivo evaluation of the pharmacokinetics of platinated agents.
Keywords :
computerised tomography; drug delivery systems; image registration; image sequences; medical image processing; 24 h; CT imaging; CT intensity; Hounsfield unit; Pt; ablated rabbit liver; image analysis; implanted polymer millirods; local carboplatin concentration; local drug release systems evaluation; molecular imaging; normal rabbit liver; pharmacokinetics; temporal CT volumes sequence; Computed tomography; Drug delivery; Image resolution; Image sequence analysis; In vivo; Magnetic resonance imaging; Monitoring; Optical imaging; Rabbits; X-ray imaging; Animals; Carboplatin; Catheter Ablation; Drug Delivery Systems; Equipment Failure Analysis; Imaging, Three-Dimensional; Liver; Male; Polymers; Rabbits; Radiographic Image Enhancement; Reference Values; Reproducibility of Results; Sensitivity and Specificity; Subtraction Technique; Tissue Distribution; Tomography, X-Ray Computed;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/TMI.2002.806270
Filename :
1174109
Link To Document :
بازگشت