DocumentCode
1131120
Title
Longitudinal aliasing in multislice helical computed tomography: sampling and cone-beam effects
Author
La Rivière, Patrick J. ; Pan, Xiaochuan
Author_Institution
Dept. of Radiol., Univ. of Chicago, IL, USA
Volume
21
Issue
11
fYear
2002
Firstpage
1366
Lastpage
1373
Abstract
In this study, we examine longitudinal aliasing properties in multislice helical computed tomography (CT) volumes reconstructed under the multiple parallel fanbeam approximation by use of a 180LI-type algorithm. We focus on the differences between the multislice case and the single-slice case, which has been studied previously. Specifically, we examine longitudinal aliasing properties in four-slice scanners for helical pitches 3 and 6, which are sometimes called "preferred" in four-slice helical CT, because it is believed that the effective longitudinal sampling intervals at these pitches are equivalent to those in single-slice helical CT operating at pitches 1 and 2, respectively. While these equivalences have been supported by comparative studies of slice-sensitivity profiles in single- and multislice helical CT, artifacts have been observed in pitch-3 and pitch-6 multislice images that were not evident in their purported single-slice counterparts. We attribute these differences to aliasing arising in the multislice reconstructions that is not present in the single-slice counterparts. We find that the aliasing has two principal origins: sampling effects similar to those in the single-slice case and cone-beam effects. The difference between the multislice, pitch-3 and single-slice, pitch-1 results is attributed to the small cone angle in multislice helical CT, which introduces inconsistencies among the measurements of different detector rows. The difference between multislice, pitch-6 and single-slice, pitch-2 results is attributed to a combination of the cone angle and genuine differences in sampling patterns. It is argued, however, that the lack of strict equivalence with single-slice counterparts does not necessarily undermine the claim that pitches 3 and 6 are "preferred" relative to other pitches in multislice helical CT.
Keywords
computerised tomography; image reconstruction; medical image processing; 180LI-type algorithm; artifacts; cone-beam effects; different detector rows; four-slice scanners; helical pitches; longitudinal aliasing; medical diagnostic imaging; multislice helical computed tomography; sampling effects; single-slice counterparts; slice-sensitivity profiles; Approximation algorithms; Collimators; Computed tomography; Detectors; Geometry; Image reconstruction; Image sampling; Radiology; Sampling methods; Sensor arrays; Artifacts; Equipment Failure Analysis; Phantoms, Imaging; Quality Control; Reproducibility of Results; Sample Size; Sensitivity and Specificity; Tomography, Spiral Computed;
fLanguage
English
Journal_Title
Medical Imaging, IEEE Transactions on
Publisher
ieee
ISSN
0278-0062
Type
jour
DOI
10.1109/TMI.2002.806428
Filename
1175085
Link To Document