• DocumentCode
    1133724
  • Title

    Test of eight superconducting arc quadrupoles for RHIC

  • Author

    Wanderer, P. ; Anerella, M. ; Ganetis, G. ; Garber, M. ; Ghosh, A. ; Greene, A. ; Gupta, R. ; Jain, A. ; Kahn, S. ; Kelly, E. ; Morgan, G. ; Muratore, J. ; Prodell, A. ; Rehak, M. ; Rohrer, E.P. ; Sampson, W. ; Shutt, R. ; Thomas, R. ; Thompson, P. ; Will

  • Author_Institution
    RHIC Project, Brookhaven Nat. Lab., Upton, NY, USA
  • Volume
    30
  • Issue
    4
  • fYear
    1994
  • fDate
    7/1/1994 12:00:00 AM
  • Firstpage
    1734
  • Lastpage
    1737
  • Abstract
    Test results from a group of eight superconducting quadrupoles made at Brookhaven National Laboratory are presented. The magnets have been designed for use in the arc regions of the Relativistic Heavy Ion Collider now under construction at Brookhaven. Novel features of the design include a single-layer coil, the use of injection-molded phenolic for the pole spacers, and a yoke that also serves as a collar. This R&D series has been used to verify the magnet quench performance and field quality prior to the start of the production run in industry
  • Keywords
    beam handling equipment; ion accelerators; magnetic fields; storage rings; superconducting magnets; superconducting transition temperature; synchrotrons; RHIC; Relativistic Heavy Ion Collider; collar; field quality; injection-molded phenolic; magnet quench performance; pole spacers; single-layer coil; superconducting arc quadrupoles; yoke; Apertures; Assembly; Colliding beam devices; Conductors; Laboratories; Production; Research and development; Superconducting coils; Superconducting magnets; Testing;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.305591
  • Filename
    305591