DocumentCode :
1134204
Title :
Partial Discharge Testing under Direct Voltage Conditions
Author :
Bever, Renate S. ; Westrom, John L.
Author_Institution :
University of the District of Columbia
Issue :
1
fYear :
1982
Firstpage :
82
Lastpage :
93
Abstract :
DC partial discharge (PD) (corona) testing is performed using a multichannel analyzer for pulse storing, and data is collected during increase of voltage and at quiescent voltage levels. Thus high voltage ceramic disk capacitors were evaluated by obtaining PD data interspersed during an accelarated life test. Increased PD activity was found early in samples that later failed catastrophically. By this technique, trends of insulation behavior are revealed sensitively and nondestructively in high voltage dc components.
Keywords :
Breakdown voltage; Conducting materials; Corona; Dielectrics; Internal stresses; NASA; Partial discharges; Residual stresses; Surface discharges; Testing;
fLanguage :
English
Journal_Title :
Aerospace and Electronic Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9251
Type :
jour
DOI :
10.1109/TAES.1982.309208
Filename :
4102620
Link To Document :
بازگشت