• DocumentCode
    1135211
  • Title

    Heat leak performance of SSC collider dipole magnets

  • Author

    Weisend, J.G., II ; Levin, M. ; Franks, D. ; Pletzer, R. ; Augustynowicz, S. ; McInturff, A.D. ; Boroski, W.

  • Author_Institution
    SCC Lab., Dallas, TX, USA
  • Volume
    30
  • Issue
    4
  • fYear
    1994
  • fDate
    7/1/1994 12:00:00 AM
  • Firstpage
    2257
  • Lastpage
    2260
  • Abstract
    The large number of superconducting dipoles in the SSC results in a stringent heat leak budget for each dipole. Ensuring that the dipoles meet this budget is vital to the successful operation of the collider. This work surveys heat leak measurements taken during 4 different magnet string tests. These tests involved both 40 mm and 50 mm aperture dipoles. In these experiments the heat leak to the 80 K shield, 20 K shield and cold mass are measured. The results are compared to predictions from a computational thermal model of the dipole cryostat. Discrepancies are seen between the predicted and measured values. Possible explanations for these discrepancies are given
  • Keywords
    beam handling equipment; cryostats; heat losses; proton accelerators; superconducting magnets; synchrotrons; 20 K; 80 K; SSC collider dipole magnets; cold mass; computational thermal model; dipole cryostat; heat leak performance; magnet string tests; shield; superconducting dipoles; Apertures; Cooling; Erbium; Laboratories; Length measurement; Performance evaluation; Resistors; Superconducting magnets; System testing; Temperature;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.305724
  • Filename