DocumentCode
1135211
Title
Heat leak performance of SSC collider dipole magnets
Author
Weisend, J.G., II ; Levin, M. ; Franks, D. ; Pletzer, R. ; Augustynowicz, S. ; McInturff, A.D. ; Boroski, W.
Author_Institution
SCC Lab., Dallas, TX, USA
Volume
30
Issue
4
fYear
1994
fDate
7/1/1994 12:00:00 AM
Firstpage
2257
Lastpage
2260
Abstract
The large number of superconducting dipoles in the SSC results in a stringent heat leak budget for each dipole. Ensuring that the dipoles meet this budget is vital to the successful operation of the collider. This work surveys heat leak measurements taken during 4 different magnet string tests. These tests involved both 40 mm and 50 mm aperture dipoles. In these experiments the heat leak to the 80 K shield, 20 K shield and cold mass are measured. The results are compared to predictions from a computational thermal model of the dipole cryostat. Discrepancies are seen between the predicted and measured values. Possible explanations for these discrepancies are given
Keywords
beam handling equipment; cryostats; heat losses; proton accelerators; superconducting magnets; synchrotrons; 20 K; 80 K; SSC collider dipole magnets; cold mass; computational thermal model; dipole cryostat; heat leak performance; magnet string tests; shield; superconducting dipoles; Apertures; Cooling; Erbium; Laboratories; Length measurement; Performance evaluation; Resistors; Superconducting magnets; System testing; Temperature;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/20.305724