Title :
Electronic Field Free Line Rotation and Relaxation Deconvolution in Magnetic Particle Imaging
Author :
Bente, Klaas ; Weber, Matthias ; Graeser, Matthias ; Sattel, Timo F. ; Erbe, Marlitt ; Buzug, Thorsten M.
Author_Institution :
Grad. Sch. for Comput. in Med. & Life Sci., Univ. zu Lubeck, Lubeck, Germany
Abstract :
It has been shown that magnetic particle imaging (MPI), an imaging method suggested in 2005, is capable of measuring the spatial distribution of magnetic nanoparticles. Since the particles can be administered as biocompatible suspensions, this method promises to perform well as a tracer-based medical imaging technique. It is capable of generating real-time images, which will be useful in interventional procedures, without utilizing any harmful radiation. To obtain a signal from the administered superparamagnetic iron oxide (SPIO) particles, a sinusoidal changing external homogeneous magnetic field is applied. To achieve spatial encoding, a gradient field is superimposed. Conventional MPI works with a spatial encoding field that features a field free point (FFP). To increase sensitivity, an improved spatial encoding field, featuring a field free line (FFL) can be used. Previous FFL scanners, featuring a 1-D excitation, could demonstrate the feasibility of the FFL-based MPI imaging process. In this work, an FFL-based MPI scanner is presented that features a 2-D excitation field and, for the first time, an electronic rotation of the spatial encoding field. Furthermore, the role of relaxation effects in MPI is starting to move to the center of interest. Nevertheless, no reconstruction schemes presented thus far include a dynamical particle model for image reconstruction. A first application of a model that accounts for relaxation effects in the reconstruction of MPI images is presented here in the form of a simplified, but well performing strategy for signal deconvolution. The results demonstrate the high impact of relaxation deconvolution on the MPI imaging process.
Keywords :
biomagnetism; deconvolution; feature extraction; image coding; image reconstruction; iron compounds; magnetic particles; medical image processing; nanomagnetics; nanomedicine; nanoparticles; superparamagnetism; suspensions; 1D excitation; 2D excitation field; FFL-based MPI imaging process; FFL-based MPI scanner; Fe3O4; administered superparamagnetic iron oxide particles; biocompatible suspensions; conventional MPI; dynamical particle model; electronic field free line rotation; field free point features; gradient field; image reconstruction; interventional procedures; magnetic nanoparticles; magnetic particle imaging; real-time image generation; relaxation deconvolution; relaxation effects; signal deconvolution; sinusoidal changing external homogeneous magnetic field; spatial distribution; spatial encoding field; tracer-based medical imaging technique; Biomedical imaging; Coils; Deconvolution; Encoding; Image reconstruction; Magnetic resonance imaging; Ferrofluid relaxation; field free line (FFL); filtered backprojection; image reconstruction; magnetic particle imaging (MPI); projection reconstruction; relaxation; superparamagnetic nanoparticles;
Journal_Title :
Medical Imaging, IEEE Transactions on
DOI :
10.1109/TMI.2014.2364891