DocumentCode :
1137388
Title :
Effect of Electrical Generator Parameters on Transient Suppressors
Author :
Erickson, J. ; Reich, B.
Author_Institution :
U.S. Army Electronics Command Fort Monmouth, N.J. 07703
Issue :
3
fYear :
1972
fDate :
5/1/1972 12:00:00 AM
Firstpage :
372
Lastpage :
376
Abstract :
In vehicular and aircraft generating systems, the voltage transient suppressor requirements for protection of utilization loads are generally based on measured values of valtage transients and the generating system impedance. This paper presents an approximate method for determining the suppressor requirements that disregards the generating system impedance. When a voltage surge due to removal of load is suppressed, the greater portion of the removed load current is transferred to the shunt-type suppressor. The influence of generating system voltage regulator design on severity of voltage transients is discussed.
Keywords :
Aerospace electronics; Aircraft; Batteries; DC generators; Impedance; Rectifiers; Regulators; Solid state circuits; Surge protection; Voltage;
fLanguage :
English
Journal_Title :
Aerospace and Electronic Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9251
Type :
jour
DOI :
10.1109/TAES.1972.309521